Used to dilate the musculofascia, renal capsule, and parenchyma to establish and maintain a percutaneous tract. The dual ports for inflation and deflation provide quick uniform pressure during inflation. When deflated, the ports provide complete fluid evacuation for simple removal of the catheter. The short, tapered tip eases insertion and requires minimal predilation, and the tip allows you to dilate the tract in close proximity to the surgical site. Radiopaque markers indicate the proximal and distal ends of the balloon. Set includes balloon catheter, sheath, and inflation device.
The products on this website are available for sale in the United States. Reference Part Numbers are not the same in all countries/regions. For products available in other countries, please choose one of our other websites from the region selector at the top of the site or contact your local Cook Medical representative.
Order Number | Reference Part Number |
Instructions for Use (IFU) |
MR Status |
Inflated Balloon Diameter mm | Balloon Length cm | Rated Burst Pressure atm | More Info |
---|---|---|---|---|---|---|---|
Set | |||||||
G46036 | UNBS-6-15 |
|
N/A | 6 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
PTFE
Included Components
Description
Quantity
Balloon catheter (radiopaque nylon)
1
Sheath – 18.0 Fr, 17 cm long
1
|
|||||||
G46037 | UNBS-6-15-CS |
|
N/A | 6 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
Clear vinyl with radiopaque stripe
Included Components
Description
Quantity
Balloon catheter (radiopaque nylon)
1
Sheath – 18.0 Fr, 17 cm long
1
|
|||||||
G46024 | UNBS-8-15 |
|
N/A | 8 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
PTFE
Included Components
Description
Quantity
Balloon catheter (radiopaque nylon)
1
Sheath – 24.0 Fr, 17 cm long
1
|
|||||||
G46038 | UNBS-8-15-CS |
|
N/A | 8 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
Clear vinyl with radiopaque stripe
Included Components
Description
Quantity
Balloon catheter (radiopaque nylon)
1
Sheath – 24.0 Fr, 17 cm long
1
|
|||||||
G30365 | UNBS-10-15 |
|
N/A | 10 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
PTFE
Included Components
Description
Quantity
Balloon catheter (radiopaque nylon)
1
Sheath – 30.0 Fr, 17 cm long
1
|
|||||||
G30357 | UNBS-10-15-CS |
|
N/A | 10 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
Clear vinyl with radiopaque stripe
Included Components
Description
Quantity
Balloon catheter (radiopaque nylon)
1
Sheath – 30.0 Fr, 17 cm long
1
|
|||||||
Balloon Catheter Only | |||||||
G46033 | UNB-6-15 |
|
N/A | 6 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
PTFE
|
|||||||
G46023 | UNB-6-15-CS |
|
N/A | 6 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
Clear vinyl with radiopaque stripe
|
|||||||
G46034 | UNB-8-15 |
|
N/A | 8 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
PTFE
|
|||||||
G46035 | UNB-8-15-CS |
|
N/A | 8 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
Clear vinyl with radiopaque stripe
|
|||||||
G30364 | UNB-10-15 |
|
N/A | 10 | 15 | 20 | Expand » |
Additional Specs
Description
-
Sheath Material
PTFE
|
|||||||
G30358 | UNB-10-15-CS |
|
N/A | 10 | 15 | 20 | Expand » |