This is a test of the news alerts
Oops there is an outage. Check back soon
The products on this website are available for sale in the United States. Reference Part Numbers are not the same in all countries/regions. For products available in other countries, please choose one of our other websites from the region selector at the top of the site or contact your local Cook Medical representative.
Order Number | Reference Part Number |
Instructions for Use (IFU) |
MR Status |
Catheter Fr | Catheter Length cm | Inflated Balloon Diameter mm | More Info |
---|---|---|---|---|---|---|---|
Set | |||||||
G14422 | 010015 |
|
N/A | 5.0 | 65 | 5 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
4
Maximum
Inflation
Pressure psi
40
Included Components
Description
Quantity
Straight safety wire guide – .028 inch (.71 mm) diameter, 145 cm length with plastic pin-vise handle
1
Radiopaque balloon catheter
1
10 mL syringe
1
|
|||||||
G14320 | 010014 |
|
N/A | 7.0 | 65 | 6 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
4
Maximum
Inflation
Pressure psi
60
Included Components
Description
Quantity
Straight safety wire guide – .038 inch (.97 mm) diameter, 145 cm length with plastic pin-vise handle
1
Radiopaque balloon catheter
1
10 mL syringe
1
|
|||||||
G14463 | 010014-S1 |
|
N/A | 7.0 | 65 | 6 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
10
Maximum
Inflation
Pressure psi
60
Included Components
Description
Quantity
Straight safety wire guide – .038 inch (.97 mm) diameter, 145 cm length with plastic pin-vise handle
1
Radiopaque balloon catheter
1
10 mL syringe
1
|
|||||||
G14782 | 010014-S6 |
|
N/A | 7.0 | 65 | 6 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
4
Maximum
Inflation
Pressure psi
60
Included Components
Description
Quantity
Straight safety wire guide – .038 inch (.97 mm) diameter, 145 cm length with plastic pin-vise handle
1
Radiopaque balloon catheter
1
10 mL syringe
1
|
|||||||
Balloon Catheter Only | |||||||
G14608 | 010005 |
|
N/A | 5.0 | 65 | 5 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
4
Maximum
Inflation
Pressure psi
40
Included Components
Description
Quantity
Radiopaque balloon catheter
1
|
|||||||
G14261 | 010004 |
|
N/A | 7.0 | 65 | 6 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
4
Maximum
Inflation
Pressure psi
60
Included Components
Description
Quantity
Radiopaque balloon catheter
1
|
|||||||
G14344 | 010010 |
|
N/A | 7.0 | 65 | 6 | Expand » |
Additional Specs
Description
-
Balloon
Length cm
10
Maximum
Inflation
Pressure psi
60
Included Components
Description
Quantity
Radiopaque balloon catheter
1
|