This is a test of the news alerts
Oops there is an outage. Check back soon
The 1A recommendation from the CDC’s* Guidelines for the Prevention of Intravascular Catheter-Related Infections, 2011 is to use a minocycline/ rifampin-impregnated catheter when process alone has not helped to reduce infection rates. Cook Spectrum PICCs are the only peripherally inserted central lines that meet the CDC’s highest recommendation for reducing CLABSIs. Guidelines for the Prevention of Intravascular Catheter-Related Infections, 2011 can be found at http://1.usa.gov/hWHldR.
For more information on Cook Spectrum Technology visit http:\\spectrum.cookmedical.com.
Used for intravenous administration of nutrient fluids, chemotherapeutic agents and other drugs for therapy. Cook Spectrum catheters are impregnated with the antibiotics minocycline and rifampin to prevent catheter-related bloodstream infections.
The products on this website are available for sale in the United States. Reference Part Numbers are not the same in all countries/regions. For products available in other countries, please choose one of our other websites from the region selector at the top of the site or contact your local Cook Medical representative.
Order Number | Reference Part Number |
Instructions for Use (IFU) |
MR Status |
Lumens |
Catheter Fr |
Catheter Length cm |
More Info |
---|---|---|---|---|---|---|---|
G36252 | PICS-401-MPIS-NT-ABRM |
|
N/A | 1 | 4 | 60 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
nitinol
|
|||||||
G36219 | PICS-401-MPIS-ABRM |
|
N/A | 1 | 4 | 60 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
stainless steel
Included Components
Description
Quantity
Soft silicone PICC
1
EchoTip® percutaneous entry needle
1
Wire guide
1
Locking Peel-Away® Introducer Sheath
1
12 mL disposable syringe
1
Hydrophilic-coated obturator
1
Disposable scalpel
1
Paper measuring tape
1
Needleless injection cap
1
StatLock® securement device
1
Catheter ID Card
1
Safety sharps container
1
|
|||||||
G36221 | PICS-501-MPIS-NT-ABRM |
|
N/A | 1 | 5 | 60 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
nitinol
|
|||||||
G36220 | PICS-501-MPIS-ABRM |
|
N/A | 1 | 5 | 60 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
stainless steel
|
|||||||
G36312 | PICDS-601-MPIS-NT-ABRM |
|
N/A | 2 | 6 | 58 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
nitinol
|
|||||||
G36314 | PICDS-601-MPIS-ABRM |
|
N/A | 2 | 6 | 58 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
stainless steel
|
|||||||
G36315 | PICDS-701-MPIS-NT-ABRM |
|
N/A | 2 | 7 | 60 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
nitinol
|
|||||||
G36316 | PICDS-701-MPIS-ABRM |
|
N/A | 2 | 7 | 60 | Expand » |
Additional Specs
Description
-
Wire Guide Diameter/Length inch/cm
.018/65
Wire Guide Material
stainless steel
|
StatLock is a registered trademark of Venetec International, Inc.